other

Fire Rated System

Home Fire Rated System

FIRE RATED GLASS

FIRE RATED GLASS

FIRE RATED GLASS

FIRE RATED GLASS

New Products
  • Description

FIRE RATED GLASS PERFORMANCE

Hwarrior PTD Ltd and SGP provide customized fire rated systems that comply with European standards. Their brand, KFORTS, is dedicated to researching globally advancing framed glass systems, offering fire rated glass, fire doors, partitions, curtain wall systems, and other security systems.

 

Hwarrior’s fire rated systems have passed European standard tests and got certifications, providing a one-stop fire rated system solution to all customers’ needs. Hwarrior owns an independent R&D team, laboratories, and manufacturing facilities, focusing on the development of fire-resistant materials and systems. In addition to fire rated systems, KFORTS also offers framed security glass systems that are resistant to burglary, bullets, and explosions.

 

KFORTS Factory, located in Zhaoqing China, has IS09001 quality management , top level CE / TUV / AS certification ,  and Singapore certification, etc. With over 20 years of experience, our factory has faced several challenges and met the quality of standards and expectation of clients. We have managed to expand our projects to regions like Europe, Asia, Australia and Africa etc.

KFORTS team is providing one-stop service including design, fabrication and installation, as below.

 

 

KFORTS fire protection system provides global users with glass frame fire protection systems that comply with European standards

KFORTS Fire Protection System - TE Series

 

Door, window, curtain wall system

The security system is owned by KFORTS, a brand under Guangdong Howell Security Technology Co., Ltd. The system is divided into fire-resistant and anti-theft series.

a. Fireproof series: developed according to the EU fire protection standards (BSEN1634-1/BSEN1364-3) and Singapore standards (SS332-2018), in compliance with local building standards

The requirements and regulations stipulated by fire prevention standards. The combination system of fire doors and fire partition walls is suitable for a wide range of fire protection levels in buildings.

b. Anti theft series: developed according to the European Union (EN1627/EN1628/EN1629/EN1630/EN356) standards and has passed the requirements specified in the standards

 

And regulations.

 

Main performance: Fire resistance

The system has been tested and certified according to different standards

> Fire prevention standards

European standard EN1063

European standard EN1522

American standard UL752

 

Product range:

I. Fireproof series

a. Fire door combination system, with a fire resistance time of up to 1 hour.

b. Fire door combination system, with a fire resistance time of up to 2 hours.

c. Fireproof partition system, with a fire resistance time of up to 1 hour.

d. Fireproof partition system, with a fire resistance time of up to 2 hours.

 

II Anti theft series

a. Security window system

b. Security door combination system

 

Compliance with laws and regulations:

a. Mechanical strength:

FSB/PSB requires glass to withstand an impact force of 600N. I) BS6206 Grade A - Impact resistance.

 

Article 2208: Resistance to Crushing

 

b. Fire prevention requirements:

25mm/45mm fire-resistant glass has stability, integrity, and insulation properties against thermal radiation.

 

It meets both the EU fire protection standards (BSEN1634-1/BSEN1364-3) and the Singapore 332:2018 fire door standard.

 

c. Installation requirements:

The Fire Prevention Code stipulates that the suitability and acceptability of fire-resistant glass systems should be evaluated on a case by case basis to clarify their intended use.

 

Consultant:

The system has received comprehensive consultation in design, manufacturing, and application to meet design and regulatory requirements. The main scope of consulting work includes:

a. Product approval

b. Specific application for approval of architectural structural drawings

c. Statutory Certificate of Conformity

 

d. Product technical consultation

 

Fire Performance Table (1)

 

Fire Protection Standards&Fireproof Glass Models
Ei60
Ei120
European Standard (Note 1) EN 357:2004   Glass in buildings, including fire-resistant glass components of transparent or semi transparent glass products, classification of fire resistance performance Ei60, 60 minute insulation and fire prevention Ei120 20 minute insulation and fire prevention
Note 1: There is no independent specification for fire-resistant glass in European standards, only requirements and code classification for building components using fire-resistant glass are provided
R load-bearing Like REI90 Wall or curtain wall with 90 minute thermal insulation and fire resistance for load-bearing purposes
E Fire resistance integrity Like RE120 120 minute non insulated fire-resistant wall or curtain wall for load-bearing purposes
W thermal radiation protection Like EIW60 Curtain walls or doors and windows that are non load bearing and require 60 minutes of thermal insulation and fire prevention, with thermal radiation not exceeding 15kW/㎡
I Insulation Like EI60 Non load bearing 60 minute thermal insulation and fireproof door, window, and curtain wall
S smoke prevention Like EIC60 Non load bearing 60 minute insulated, fire-resistant, and smoke proof doors and windows
C automatically shuts down Like EIC60 Non load bearing doors and windows that can be insulated, fire-resistant, smoke proof, and automatically closed for 60 minutes

 

 

Overview

Product specifications

To ensure the quality and reliability of the products, they are all produced by KFORTS, a brand under Guangdong Howell Security Technology Co., Ltd., and their structural safety meets the requirements

Standard fireproof series. Existing fire door combination system and firewall system

a. The fire door combination system consists of glass fire doors and glass fire partition systems.

b. The fireproof partition system consists of fireproof glass partitions.

The above system meets the fire resistance requirements of BS476t 22-23 in terms of stability, integrity, and insulation, ranging from 1 hour to 2 hours. The system uses tempered steel

 

Made of safety glass and fire-resistant materials, designed to prevent cutting injuries and prohibit forced entry.

 

glass

a. The fire-resistant series is made of tempered glass and fire-resistant materials bonded together, with characteristics such as fire resistance, high transparency, heat insulation, and radiation resistance. Its optical clarity and transparency

The brightness is equivalent to float glass.

b. The glass has passed the mechanical impact tests of BS6206, AS2208, and BS5544. The experiment proved that the glass did not penetrate or break. It belongs to

Laminated glass is a type of safety glass that is not easily cut when broken. The glass used can be processed in color, texture, or sandblasting.

 

c. The glass has passed the BSEN12600:2002 impact test, which ensures that multiple layers will not form bubbles when exposed to solar radiation and adverse weather conditions.

 

 

leave a message
If you are interested our products and services,please leave us messages here to know more details. We will reply as soon as possible.
Send

RELATED PRODUCTS

TANAN MERAH KECHIL LINK
TANAN MERAH KECHIL LINK
TANAN MERAH KECHIL LINK
Our Products

Copyright @ 2025 HWARRIOR PTE LTD All Rights Reserved. Network Supported Network Supported

Sitemap Blog Xml Privacy Policy

leave a message

leave a message
If you are interested our products and services,please leave us messages here to know more details. We will reply as soon as possible.
submit

Home

Case

whatsApp

contact