other

Ensure Your Safety in Different Scenarios

Home Ensure Your Safety in Different Scenarios

Burglarproof Glass System

New Products

Burglarproof Glass System

 

1. Burglarproof Glass System: Burglar Resistance Performance

 

Standards TR1 TR2 TR3 notes
European Standards

EN1627

Pedestrian doorsets, windows, curtain walling, grilles and shutters—Burglarproof resistance—Requirements and classification

RC3 RC4

RC6*

Note*: KFORTS TR series includes glass door systemswindow systems, curtain wall systems, etc. KFORTS can customize your products with one or more resistance performance based on your requirements.

EN1628

Pedestrian doorsets, windows, curtain walling, grilles and shutters—Burglarproof resistance—Test method for the determination of resistance under static loading

6KN 10KN 15KN

EN1629

Pedestrian doorsets, windows, curtain walling, grilles and shutters—Burglarproof resistance—Test method for the determination of resistance under dynamic loading

Resist 50KG pendulum impactor from a height of 750mm.

No test.**

No test.**

EN1630

Pedestrian doorsets, windows, curtain walling, grilles and shutters—Burglarproof resistance—Test method for the determination of resistance to manual burglary attempts

Resist tools specified in RC1-RC3 systems, such as 700mm length crowbars and hand drills.

Resist tools specified in RC1-RC4 systems, such as 0.8KG weight axes and battery drills.

Resist tools specified in RC1-RC6 systems, such as 1.1KW saber saws and 2.3KW angle grinders.

Note **: The purpose of EN1629 dynamic impact test is to simulate human attacks without the use of tools, such as shoulder strikes or kicks. When testing RC4-6 systems, the static load shall far exceed the dynamic load, which will not be achieved manually. Therefore, RC4-6 systems do not require dynamic mechanical test.

EN356

Glass in building—Security glazing—Testing and classification of resistance against manual attack

P5A

Resist impact 3 times by a  100mm diameter, 4.11KG weight steel ball from the 9 meters height.

P6B

Resist 30-50 times of the impact by a 2KG axe.

P8B

Resist over 70 times of the impact by a 2KG axe.

 

2. Tools and Firearms that TR systems can resist

The resistance performance of TR1 system is equivalent to RC3 resistance level in European standards.

TR1 system can withstand destructive tools and firearms as follows.

 

Tool number Tool specification description
A.1

Screwdriver; Flat blade, length (365 ± 25) mm, blade width (16 ± 2,2) mm

A.2

Steel wire; Various diameters up to a maximum diameter of 4 mm, including steel and electrical wire. No restriction on length

A.3

Locksmiths hammer; head weight (200 ± 20) g, length (300 ± 20) mm

A.4

Pipe wrench; length (240± 20) mm

A.5

Set of pin punches; diameters between 3 mm and 10 mm

A.6

Set of drill-bits; HSS or HS/CO parallel shank twist drills (jobber), Ø 1,0 mm to Ø6,0 mm in steps of 0,5 mm. Only one drill bit of each diameter may be used

A.7

Universal lock key; including cabinet lock and profile cylinder functions

A.8

Hand drill; maximum length 355 mm

A.9

Hacksaw, with two bimetals or HSS blades, blade length (330 ± 30) mm

A.10

 

Multiple slip joint gripping pliers; maximum length 260 mm

A.11

 

Steel wire; Various diameters up to a maximum diameter of 4 mm, including steel and electrical wire. No restriction on length

A.12

 

Pistol; Gun type 54 with 7,62 mm bullets

 

The resistance performance of TR2 system is equivalent to RC4 resistance level in European standards.

TR2 system can withstand destructive tools and firearms as follows.

 

Tool number Tool specification description
B.1

Club hammer; length (300 ± 25) mm, head weight (1,25 ± 0,1) kg

B.2

Cold chisel; length (250 ± 25) mm, blade width (30 ± 5) mm

B.3

Wood chisel; length (350 ± 25) mm, blade width (30 ± 5) mm

B.4

Plate shears; left cutting and right cutting, length (260 ± 25) mm

B.5

Axe; length (350 + 25) mm, head weight (800 ± 30) g

B.6

Bolt-cutter; length (460 ± 50) mm

B.7

Cordless drilling machine; Without percussion action, with two nominal 14,4 V battery packs (up to 3,2 Ah each)

B.8

Set of drill-bits; HSS or HS/CO parallel shank twist drills (jobber), Ø 1,0 mm to Ø 13,0 mm in steps of 0,5 mm. Only one drill bit of each diameter may be used

B.9

Submachine gun; Gun Type 79 with 7,62 mm bullets

 The resistance performance of TR3 system is equivalent to RC6 resistance level in European standards.

TR3 system can withstand destructive tools and firearms as follows.

 

Tool number Tool specification description
C.1

Spalling hammer; length (800 + 50) mm, head weight (3,5 ± 0,25) kg

C.2

Discs; Ø 230 mm maxi, thickness 3,0 mm (for steel or stone excluding diamond)

C.3

Saw blades; bimetal

C.4

Steel wedges; length (200 ± 10) mm, width (80 ± 10) mm, height (40 ± 5) mm

C.5

Electric jig saw; nominal 650 W± 10 %

C.6

Angle grinder; Nominal 2 300 W± 10 %, disc diameter max 230 mm

C.7

Electric drill; Nominal 1 050 W± 10 %, with percussion action

C.8

Submachine gun; Gun Type 56 with 7,62 mm bullets

C.9

Sniper rifle; Gun Type 79 with 7,62 mm bullets

3. More Performances: Building physics

Besides KFORTS high security performance, TR system complies with all requirements in building physics up to highest level. It features a slim frame, a concealed sash design, and a wide visible area.

Resistance against wind load

Water tightness

Air permeability

Technical parameters: ≥ 16kpa/m ³ (1800 * 1500), Technical parameters: ≥ 700 (PA), Technical parameters:
The unit seam length index value is ≤ 0.5m ³ (m · h),The unit area index value is ≤ 1.4 square meters (m · h),Level: 8 (max).

Air permeability

Sound Insulation

Standard: EN673 Standard: GB/T 8485-2008,

Technical parameters: 1.87-2.15 W/(㎡· k)

Door: 2.158 W/(㎡· k)

Window: 1.875 W/(㎡· k)

Curtain Wall: 1.873 W/(㎡· k)

Technical parameters: ≥ 45 (dB (A)),

 

 

4. Design and Sections

TR Security Glass Window System 

Design examples

 

 

TR Security Glass Window System  

Section Examples

TR Security Glass Swing Door and Curtain Wall System 

Design examples

 

TR Security Glass Swing Door and Curtain Wall System 

Section examples

 

TR Security Glass Sliding Door System

Design examples

 

TR Security Glass Sliding Door System

              Section examples

 

 

 

Our Products

Copyright @ 2024 HWARRIOR PTE LTD All Rights Reserved. Network Supported Network Supported

Sitemap Blog Xml Privacy Policy

leave a message

leave a message
If you are interested our products and services,please leave us messages here to know more details. We will reply as soon as possible.
submit

Home

Case

whatsApp

contact